3U/16 bays, 4Gb Fibre-SAS/SATA RAID
Subsystem
Features
-
Supports RAID levels 0, 1, 0+1, 3, 5, 6, 30, 50, 60 and JBOD
-
Supports online Array roaming
-
Online RAID level/stripe size migration
-
Online capacity expansion and RAID level migration
simultaneously
-
Online Volume Set Expansion
-
Supports multiple array enclosures per host connection
-
Supports greater than 2TB per volume set (64-bit LBA support)
-
Supports 4K bytes/sector for Windows up to 16TB per volume set
-
Supports up to 128 LUNs per RAID set
-
Transparent data protection for all popular operating systems
-
RAID ADG provides the highest level of data protection
-
Instant availability and background initialization
-
Supports S.M.A.R.T, NCQ and OOB Staggered Spin-up capable
drives
-
Local audible event notification alarm.
-
Supports password protection and UPS connection
-
Serial port interface for remote event notification
-
Redundant flash image for high availability
Specification
|
Model |
SB-3163S-F4S3 |
|
Form-factor |
3U 19-inch rackmount
chassis |
|
RAID Controller |
Intel
IOP341 64-bit |
|
RAID level |
0,1,0+1,3,5,6,30,50,60 and JBOD |
|
Cache memory |
512MB ~
2GB DDR2 SDRAM |
|
Host bus interface |
FC-AL (4
Gb/s) per port |
|
Drive bus interface |
SAS or
3Gb/s SATA II |
|
Data transfer rate |
Up to
400MB/sec per channel |
|
Expansion |
One 4x
mini SAS (SFF -8088) |
|
Controller Redundancy |
Option
|
|
Hot-swap drive trays |
Sixteen (16) 1-inch trays |
|
Online capacity expansion,
RAID level / stripe size
migration |
Yes |
|
Online Volume sets
expansion |
Yes |
|
Online Array roaming |
Yes |
|
Online consistency check |
Yes |
|
SMTP manager and SNMP
agent |
Yes
|
|
E-mail Notification |
Yes |
|
Redundant Flash image |
Yes
|
|
R-Link support
|
Yes |
|
Support over 2TB per
volume |
Yes
|
|
Instant availability and
background initialization |
Yes |
|
S.M.A.R.T. support |
Yes
|
|
New disk insertion /
removal detection |
Yes |
|
Failed drive auto rebuild |
Yes
|
|
Continuous rebuild |
Yes
|
|
Multiple RAID selection |
Yes |
|
Bad block auto-remapping |
Yes
|
|
Audial alarm |
Yes |
|
Password protection |
Yes
|
|
UPS connection |
Yes |
|
SES2 enclosure
management
|
Yes
|
|
Hot-swap power supplies |
Yes |
|
Cooling fans |
Two(2) 460W power supplies w/PFC
|
|
Battery backup |
4 |
|
Power requirements |
Option
|
|
Environmental |
AC 90V ~ 264V Full Range
8A ~ 4A, 47Hz ~ 63Hz |
|
Relative Humidity |
10% ~ 85% Non-condensing |
|
Operating Temp |
10oC ~ 40oC (50oF ~ 104oF)
|
|
Physical
Dimension |
133(H) x 482(W) x 600(D)mm |
|
Weight (Without Disk) |
24.7kgs/54.34Lbs
|
|
|