SB-2123-S3S3
Data Sheet |
Manual
2U/12 bays, 3Gb SAS-SAS / SATA II
RAID subsystem
Features
-
Supports RAID levels 0, 1, 3, 5, 6, 30, 50, 60 and JBOD
- Supports online Array
roaming
- Online RAID level/stripe
size migration
- Online capacity expansion
and RAID level migration
simultaneously
- Online Volume Set
Expansion
- Supports multiple array
enclosures per host connection
- Supports greater than 2TB
per volume set (64-bit LBA support)
- Supports 4K bytes/sector
for Windows up to 16TB per volume set
- Support spin down drives
when not in use to extend service
(MAID)
- Transparent data
protection for all popular operating systems
- RAID ADG provides the
highest level of data protection
- Instant availability and
background initialization
- Supports S.M.A.R.T, NCQ
and OOB Staggered Spin-up capable
drives
- Supports hot spare and
automatic hot rebuild
- Local audible event
notification alarm
- Supports password
protection and UPS connection
- Built-in serial port
interface for remote event notification
- Redundant flash image for
high availability
Specification
|
Model |
SB-2123-S3S3 |
|
Form-factor |
2U 19-inch rackmount
chassis |
|
RAID Controller |
Intel
IOP341 64-bit |
|
RAID level |
0, 1, 3,
5, 6, 30, 50, 60 and JBOD |
|
Cache memory |
512MB ~
2GB DDR2 SDRAM |
|
Host bus interface |
SAS
(3Gb/s) per port |
|
Drive bus interface |
SAS or
3Gb/s SATA II |
|
Data transfer rate |
Up to
400MB/sec per channel |
|
Expansion |
One 4x
mini SAS (SFF -8088) |
|
Hot-swap drive trays |
Twelve (12) 1-inch trays
|
|
Online capacity expansion,
RAID level / stripe size
migration |
Yes |
|
Online Volume sets
expansion |
Yes |
|
Online Array roaming |
Yes |
|
Online consistency check |
Yes |
|
SMTP manager and SNMP
agent |
Yes
|
|
E-mail Notification |
Yes |
|
Redundant Flash image |
Yes
|
|
R-Link support
|
Yes |
|
Support over 2TB per
volume |
Yes
|
|
Instant availability and
background initialization |
Yes |
|
S.M.A.R.T. support |
Yes
|
|
New disk insertion /
removal detection |
Yes |
|
Failed drive auto rebuild |
Yes
|
|
Continuous rebuild |
Yes
|
|
Multiple RAID selection |
Yes |
|
Bad block auto-remapping |
Yes
|
|
Audial alarm |
Yes |
|
Password protection |
Yes
|
|
UPS connection |
Yes |
|
SES2 enclosure
management
|
Yes
|
|
Hot-swap power supplies |
Yes |
|
Cooling fans |
Two(2) 350W power supplies w/PFC
|
|
Battery backup |
2 |
|
Power requirements |
Option
|
|
Environmental |
AC 90V ~ 264V Full Range
8A ~ 4A, 47Hz ~ 63Hz |
|
Relative Humidity |
10% ~ 85% Non-condensing |
|
Operating Temp |
10oC ~ 40oC (50oF ~ 104oF)
|
|
Physical
Dimension |
88(H)x482(W)x650(D)mm |
|
Weight (Without Disk) |
13.5kgs/29.7Lb
|
|